Resource:

A16E-G2130 DataSheet
 
 
ES A16E-G2130-4
The A16E leverages the existing TCP/IP network infrastructure by encapsulating data in iSCSI protocols. The A16E comes with 4 GbE data ports and all Infortrend's standard RAID functions. The A16E-G2130-4 delivers flexibility, ease of management, and configuration simplicity, while ensuring maximum security and protection for your precious data.

The A16E-G2130-4 subsystem is a power-boost version of Infortrend's iSCSI series with hardware RAID6 (by the latest ASIC400), RoHS-compliant hardware, and 1GB more internal bandwidth than previous EonStor. With abundant bandwidth and computing power, the iSCSI RAID comes with four (4) GbE host ports and is able to satisfy the increasing demands for storage space with block-level performance and the unparalleled RAID5 and RAID6 protection. Leading the trend of intelligent RAID storage, the A16E is a seamless integration of Infortrend's innovative RAID technologies with iSCSI protocols that encapsulate SCSI data blocks and carry them over sophisticated Ethernet infrastructures. With the EonPath™ multi-path software and intelligent load-balancing algorithms, the subsystem readily joins into environments requiring a reliable storage pool. The subsystem is designed for a wide variety of applications, be it a quick addition to departmental needs, data warehousing, databases, or as a secondary storage besides a large storage network.

Reliability
Infortrend's RAID subsystems are renowned for a complete list of RAID configuration choices in terms of RAID levels, performance parameters, and proactive fault management. A configured RAID array is not only protected by drive redundancy, but also the rich variety of protection features ranging from media error recovery to the management of faulty components. EonPath multipathing drivers are now available for application servers running Windows, Solaris, or Linux operating systems. EonPath provides mutlipath IO function by recognizing and managing the fault-tolerant data paths to an individual RAID volume. Greater reliability is achieved through the path failover mechanism in the event of cabling component failure. The EonPath also comes with loadbalancing algorithms which help accelerate the throughput across host-storage data links.

Availability
Throughout the decade, our sophisticated firmware core runs a million RAID arrays around the globe, in numerous applications and harsh environments. To ensure a high level of system availability, critical components such as power supplies and cooling fans are configured in redundant pairs. Modules are integrated with the main signal path PCB via board-to-board or interface-specific connectors to eliminate points of failure. Assisted by GUI management software, an administrator is constantly aware of all component statuses through a local or remote console.

Manageability
All critical components are housed in their own removable canisters, including hard disk drives, power supplies, battery module, and cooling fans. In the event of component failure, each can be replaced within seconds. A variety of configuration and monitoring methods are available, either locally via the LCD keypad, text-mode terminal emulation, or remotely through the browser-based or Java-based SANWatch(Storage management suite). All fault conditions, including module failure, abnormal voltage and temperature readings, are instantly reported.

  • Overview
  • Specifications

 

  • Compliant with IETF iSCSI
  • iSCSI Gigabit (Gb) Ethernet to SATA-II (3Gbps) RAID subsystem
  • Four (4) GbE host ports plus one (1) Fast Ethernet port for management
  • EonPath™ multipathing driver
  • Supports up to 32 host access
  • Intelligent load-balancing; internally & between host links by the
  • Hardware RAID6 XOR engine by dedicated ASIC400 chipsets
  • Access control over IP, IQN, and mutual CHAP
  • Comprehensive browser-based RAIDWatch GUI.
  • SATA S.M.A.R.T., and NCQ support
  • Sixteen (16) SATA-II, 3Gb drive bays; backward compatible with SATA-I
  • Comprehensive management tools and event notification methods
  • Support for iSCSI initiators compliant with IETF iSCSI standard (RFC 3720)
Host-to-Drive Interface Configuration Model Form Factor
iSCSI to SATA-II (3Gbps) Single A16E-G2130-4 3U rack-mount


 

RAID Controller

  1. Hardware RAID parity computing
  2. Supports RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, and NRAID
  3. Configurable stripe size and write policy per array
  4. Multiple Global, Dedicated, & Enclosure-specific hot-spares
  5. Intelligent Drive Handling:
    1. In degraded mode: skips irreparable blocks to continue rebuild
    2. In normal operation: data-block verification and repair
  6. DDR Memory up to 2GB

Host Interface

  1. Four (4) 1Gbps Ethernet
  2. Jumbo Frame support
  3. Concurrent I/O commands
  4. Tagged command queuing up to 256

Drive Interface

  1. Sixteen (16) 3.0Gbps SATA-II (3Gbps) , hot-swappable drive trays
  2. Accommodates 1-inch pitch, 3.5-inch SATA-II (3Gbps) or SATA-I disk drives
  3. S.M.A.R.T. and NCQ support
  4. Automatic bad-sector reassignment
  5. Dedicated bandwidth to each connected drive

System Components

  1. Heavy duty 3U enclosure
  2. One (1) RAID and I/O management controller module
  3. One (1) 512MB DDR RAM DIMM module (default, supports up to 2GB in size)
  4. Two (2), hot-swappable, redundant, 530W power supply units
  5. Two (2), redundant, dual-speed cooling modules
  6. Sixteen (16), hot-swappable drive trays
  7. Two (2) forearm handles
  8. Optional, Li-Ion, life expectancy-aware battery backup unit (BBU)

Management

  1. COM1 serial port for local access to firmware-embedded utility
  2. COM2 for UPS connection
  3. GUI, Telnet, and SSH system monitoring via Ethernet
  4. Java-based SANWatch software
  5. Widest range of event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
  6. LCD keypad panel to all configuration options
  7. Event log in reserved space; Administrator's activity log
  8. Module status LED indicators:
  9. Two (2) per drive tray
  10. Seven (7) per controller module
    1. One (1) per power supply unit
    2. One (1) per BBU module
    3. Two (2) per cooling module
  11. Module failure alert through I 2 C bus

Interfaces

  1. Four (4) RJ-45 ports for Cat5e Ethernet networks
  2. One (1) Fast Ethernet management port
  3. Two (2) serial COM port (38400, n, 8, 1)
Power Supply Module
Two (2) redundant hot-swappable power supplies with PFC
Input 100VAC at 9A, 240VAC at 4.5A 530W with PFC (auto-switching)
  47 to 63Hz
Output (Maximum output: 530 Watts)
  +12.0V 30A max.
  +5.0V 32A max.
  +3.3V 30A max.
Cooling Module
Two (2) redundant dual-fan cooling modules
Maximum air flow high speed: 90CFM
  low speed: 70CFM
Environmental Specifications  
Operating temperature 0° to 40°C (35°C if battery is applied)
Non-operating temperature - 40° to 60°C
Relative humidity 5 to 95%, non-condensing
Operating altitude Operating: 0 to 12,000 ft
  Non-operating: 0 ot 40,000 ft

Dimensions:

  1. Chassis without handles: 445(W) x 130(H) x 488.2(D) mm (17.5 x 5.1 x 19.2 inches)
  2. Chassis with handles: 482.6(W) x 131(H) x 504.3(D) mm (19 x 5.2 x 19.9 inches)
  3. Package: 423(H) x 567(W) x 772(D) mm (16.7 x 22.3 x 30.4 inches)

System weight:

  1. Net weight: 28.5Kg
  2. Gross weight: 32kg (without drives)