Raya Andish Co.
Future belongs to those who see it first



 Product

 About Us

 Technical

 Contact Us
 

EonStor™ A12U-G2421
2U Profile, Single-controller, Dual SCSI-320 Host Channels 12-drive SATA-II RAID Subsystem

  • SCSI-320 to SATA-II single controller RAID subsystem
  • Hardware XOR engine by dedicated ASIC266 chipsets
  • Dual-speed fans to reduce noise
  • Enhanced modular enclosure design
  • DDR Memory up to 2GB


Infortrend's RAID functionality is unmatched in the industry in terms of its wide variety of array configuration, maintenance, and monitoring capabilities. The SCSI-to-SATA series provides IT professionals with versatile options to meet their needs. The subsystem provides two SCSI-320 host channels with 12 drive bays for SATA-II disk drives in a smartly managed enclosure. The subsystem combines massive storage capacity with SATA-II benefits, such as high performance and dedicated bandwidth, in a safe environment where the highest level of data availability is assured. High throughput is available by segregating I/O traffic across the separate PCI-X buses, while IOPS performance is delivered through the internal buffer on the XOR engine and CPU with the help of intelligent firmware algorithms.

Enclosure management
In addition to RAID protection for the disk drives, thePSUs and cooling modules are both redundant and hot-swappable modules. Even the battery backup module can be replaced online. The rotation speed of the enclosure's dual-speed fans is controlled by the firmware. In critical conditions, e.g., PSU or fan failure, the fan rotation speed is automatically raised to a higher level. Control over caching behaviors is a user-configurable option. In the event of component failures, such as UPS failure or low battery charge, the firmware stops caching write requests in cache memory.

High Performance
Featuring two (2) 64-bit 133MHz data buses, the subsystem's high data throughput is more than sufficient for small-to-medium-sized servers or workstations. Robust functionality and adaptive algorithms facilitate chip-level operation that is already fast and flexible. For example, a timeout can be configured for individual drive response time. If a specific disk drive fails to respond in time, the firmware accumulates data from the adjacent stripes of the array to maintain a fast return of data. The adaptive designs assure throughput for a wide range of applications running on Windows 2000/2003/XP-, Linux-, or Unix-based servers. Ideal applications include disk-to-disk backup, database, file, business network, storage consolidation and others.

Manageability
The EonStor A12U include a number of interface features to keep users constantly aware and automatically notified of array status. The subsystem comes standard with an Ethernet port for local or remote management using simple telnet protocol or the feature-rich RAIDWatch Java GUI. The RAIDWatch manager provides graphical presentations of array components, monitoring windows, and all configuration options. Additionally, the built-in LCD keypad panel displays event messages and provides onsite access to all firmware features.

Intelligent Drive Handling
If two bad blocks occur on two member drives of an array, the integrity of the stored data is endangered. Media Scan, Infortrend's innovative intelligent drive handling function, retrieves data from the damaged sectors. Media Scan handles low quality drives in both the degraded mode and during the rebuild process. For additional data security, other intelligent drive handling features include the transparent resetting of non-responsive hard drives, power-failure management and bad-drive handling during LD expansion.

Specifications

RAID
Multiple arrays configurable with dedicated or global hot spares
RAID levels supported: RAID 0, 1 (0+1), 3, 5, 10, 30, 50, NRAID and JBOD
Online expansion by:

  • Adding new drives
  • Copying and replacing drives with drives of larger capacit

Automatic background rebuilds
Configurable stripe size and write policy per array
Intelligent drive handling:

  • In degraded mode: skips irreparable blocks to continue rebuild
  • In normal operation: data-block verification and repair

Host Interface

  • Two (2) SCSI-320 through four (4) VHDCI 68-pin SCSI ports; SCSI-160 backward compatible
  • Concurrent I/O commands
  • Tagged command queuing up to 256
  • Variable stripe size per logical drive
  • Optimization setting for random or sequential I/Os
Drive Interface
  • Twelve (12) 3Gbps SATA-II, hot-swappable drive trays that accommodate 1-inch pitch, 3.5-inch SATA-I or SATA-II disk drives
  • Automatic bad-sector reassignment
  • Dedicated bandwidth to each connected drive
System Components
Single controller configuration provides full RAID functionalities
  • One (1) EonStor® enhanced 2U enclosure
  • One (1) RAID controller module
  • One (1) 256MB DDR RAM DIMM module (pre-installed on the controller module)
  • Two (2), hot-swappable, redundant, 350W power supply units
  • Three (A12U) or Two (A08U), hot-swappable, redundant, single-fan cooling modules running in high/low speeds
  • Twelve (12) or eight (8), hot-swappable drive trays
  • Two (2) front handles
  • Optional battery backup unit
Management
Front LCD control panel for setup and configuration
10/100 BaseT Ethernet for out-of-band management
One (1) RS-232C serial port for local access to firmware-embedded utility
Firmware-embedded Java-based RAIDWatch® GUI manager:
  • VT-100 terminal emulation via RS-232C
  • Telnet access via onboard Ethernet port
  • Cross-platform, remote administration with SSL
  • Out-of-band access via Ethernet
  • Centralized management to monitor and administer multiple RAID units on one screen

Configuration client for real-time event notification over Email, Fax, LAN broadcast, SNMP Traps, MSN messenger, ICQ, SMS short messages, and the configuration utility screen

SNMP agent support:

  • SNMP trap event notification with plain-text event message (no MIB file required)
  • SNMP V2.0 MIB file support with get-and-set commands
Indicators
Onboard alarm is triggered when one of the following modules fails:
  • RAID controller module
  • Cooling module
  • Power supply unit
  • Hard drive
  • BBU module
Module status LED indicators:
  • Two (2) per drive tray
  • Two (2) per cooling module
  • One (1) per power supply unit
  • One (1) per BBU module
  • Three (3) per LCD panel
  • Five (5) per RAID controller module
  • Two (2) per Ethernet port

Intelligent Drive Handling
If two bad blocks occur on two member drives of an array, the integrity of the stored data is endangered. Media Scan, Infortrend's innovative intelligent drive handling function, retrieves data from the damaged sectors. Media Scan handles low quality drives in both the degraded mode and during the rebuild process. For additional data security, other intelligent drive management features include the transparent resetting of hung hard drives, power-failure management, and bad-drive handling during LD expansion.

Task Scheduler
The Task Scheduler is combined with Media Scan so that the scanning operation can be scheduled beginning at a specified start time and repeating at the configurable intervals. The operation is thus hands free. Each such schedule can be defined to operate on individual hard drives, all drives of a certain class, all member drives of a specified logical drive, or all member drives of all logical drives.

Interfaces

  • Four (4) ports in two (2) dual-stacked VHDCI SCSI connectors
  • One (1) COM port (38400, n, 8, 1)
  • One (1) 10/100BaseT Ethernet port
Power Supply Module
Two (2) redundant hot-swappable power supplies with PFC
Input: 100VAC at 6A, 240VAC at 3A with PFC (auto-switching)
47 ~ 63Hz
Output: (Maximum output: 350 Watts)
  +12.0V 25A max.
  + 5.0V 25A max.
  + 3.3V 20A max.


Cooling Module

Three (A12U) redundant single-fan cooling modules

Input: 100VAC at 6A, 240VAC at 3A with PFC (auto-switching)47 ~ 63Hz


Environmental Specifications

Operating temperature: 0° to 40°C
Non-operating temperature: - 40º to 60ºC
Relative humidity: 5 ~ 95%, non-condensing
Operating altitude: Operating: 0 ~ 12,000 ft
Non-operating: 0 to 40,000 ft


Dimensions:

  • Chassis without handles: 446(W) x 88(H) x 490(D) mm
  • Chassis with handles: 482 (W) x 88(H) x 505(D) mm
  • Package: 381H x567W x 772D mm

System weight (w/o drives):

  • Net weight: 23.5kg
  • Gross weight: 25kg