Raya Andish Co.
Future belongs to those who see it first
|
Product
About Us
Technical
Contact Us |
| |
EonStor® A16F-R2431
DUAL Controller FIBER to SATA II
3U/16-bay RAID Subsystem |
|
- FC-4G to SATA-II RAID subsystem
- Eight (8) FC-4G host ports w/ onboard bypass
- Redundant, active-active RAID controllers
- Hardware RAID6 XOR by dedicated ASIC400 chipsets
- Intelligent load-balancing; internally & between host links by the EonPath™ multi-path software
- Proactive parity and media error manual and scheduled scan/repair
- High-availability, modular enclosure design
- Adaptive writer policy
- Up to 2GB cache per controller
|
|
RAID Controller
- Hardware RAID parity computing
- Supports RAID 0, 1 (0+1), 3, 5, 6, 10, 30, 50, 60, and NRAID
- RAID Migration
- Configurable stripe size and write policy per array
- Multiple Global, Dedicated, & Enclosure-specific hot-spares
- Intelligent Drive Handling:
- In degraded mode: skips irreparable blocks to continue rebuild
- In normal operation: data-block verification and repair
Host Interface
- Eight (8) FC-4G host port w/HUB functions
- Concurrent I/O commands
- Tagged command queuing up to 256
- Adaptive cache write policies
Drive Interface
- Sixteen (16) 3.0Gbps SATA-II, hot-swappable drive trays
- Accommodates 1-inch pitch, 3.5-inch SATA-II disk drives
- S.M.A.R.T. and NCQ support· Automatic bad-sector reassignment
- Dedicated bandwidth to each connected drive
System Components
- Heavy duty 3U enclosure
- Dual-redundant RAID controller modules
- One (1) 512MB DDR RAM DIMM module (default, supports up to 2GB in size) on each controller
- Two (2), hot-swappable, redundant, 530W power supply units
- Two (2), redundant, dual-speed cooling modules
- Sixteen (16), hot-swappable drive trays
- Two (2) forearm handles
- LCD keypad panel
- Li-Ion, life expectancy & charge level aware battery backup unit (BBU)
Management
- COM1 serial port for local access to firmware-embedded utility
- COM2 for UPS connection
- GUI, Telnet, and SSH system monitoring via Ethernet
- Browser-based or Java-based RAIDWatch manager software
- Firmware-embedded manager via RS-232C (audio jack) that is platform independent
- Widest range of event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
- LCD keypad panel to all configuration options
- Variable logical drive options per DIMM size
- Module status LED indicators:
- Two (2) per drive tray
- Seven (7) per controller module
- One (1) per power supply unit
- One (1) per BBU module
- Two (2) per cooling module
- Module failure alert through I 2 C bus
Interfaces
- One (1) Fast Ethernet management port
- Two (2) serial COM port (38400, n, 8, 1)
Power Supply Module Two (2) redundant hot-swappable power supplies with PFC
Input |
100~240VAC with 530W PFC (auto-switching) |
47 to 63Hz |
Output |
(Maximum output: 530 Watts) |
+12.0V |
30A max. |
+ 5.0V |
32A max. |
+ 3.3V |
32A max. |
Cooling Module
Two (2) redundant dual-fan cooling modules
| Maximum air flow: |
High speed: 90 CFM
Low speed: 70 CFM |
Environmental Specifications
Operating temperature: |
0º to 40ºC (35ºC w/ battery) |
Non-operating temperature: |
- 40º to 60ºC |
Relative humidity: |
5 to 95%, non-condensing |
Altitude: |
Operating: sea level to 12,000 ft
Non-operating: sea level to 40,000 ft |
Dimensions:
- Chassis without handles: 445(W) x 130(H) x 488.2(D) mm (17.5 x 5.1 x 19.2 inches)
- Chassis with handles: 482.6(W) x 131(H) x 504.3(D) mm (19 x 5.2 x 19.9 inches)
- Package: 423(H) x 567(W) x 772(D) mm (16.7 x 22.3 x 30.4 inches)
System weight:
- Net weight: 28kg
- Gross weight: 31kg (without drives)
|
|
|
|
|
|
|
|
|