Raya Andish Co.
Future belongs to those who see it first



 Product

 About Us

 Technical

 Contact Us
  EonStor® S16F-R1430
DUAL Controller FIBER to SAS/SATA II 3U/16-bay RAID Subsystem


  • Dual-active controller
  • 4G FC to SAS or SATA-II disk drives
  • Eight (8 - R1430) 4G FC host ports
  • Hardware RAID5 and RAID6 engine by dedicated ASIC400 chipsets
  • EonPath™ multipathing sotware





 

Specifications

RAID Controller

  • Hardware RAID parity computing
  • Hardware RAID5 & RAID6 parity computation
  • Supports RAID 0, 1 (0+1) , 3, 5, 6, 10, 30, 50, 60, and NRAID
  • RAID Migration
  • Configurable stripe size and write policy per array
  • Multiple Global, Dedicated, & Enclosure-specific hot-spares
  • Intelligent Drive Handling:
    • In degraded mode: skips irreparable blocks to continue rebuild
    • In normal operation: data-block verification and repair

Host Interface

  • Eight (8) 4G FC
  • 4Gb/s via short-/long-wavelength LC-type SFP
  • Concurrent I/O commands
  • Tagged command queuing up to 1024 Max
  • command queue up to 1024
  • Fault-tolerant host links via onboard bypass

Drive Interface

  • Sixteen (16) 3.0Gbps SAS, hot-swappable drive trays
  • Accommodates 1-inch pitch, 3.5-inch SAS or SATA-II disk drives
  • S.M.A.R.T. and NCQ support
  • Automatic bad-sector reassignment
  • Dedicated bandwidth to each connected drive

System Components

  • Heavy duty 3U enclosure
  • Dual- (R1430) RAID and I/O management controller module
  • Fault-tolerant modules interfaced through a common backplane
  • High availability SAS domains to hard drives via expanders and port selectors
  • One (1) 512MB DDR DIMM module (default, supports up to 2GB in size)
  • Redundant, hot-swappable 530W power supply units
  • Redundant, dual-speed cooling modules
  • Sixteen (16), hot-swappable drive trays
  • Two (2) forearm handles
  • Li-Ion, life expectancy-aware battery backup unit (BBU)

Management

  • COM1 serial port for local access to firmware-embedded utility
  • COM2 for UPS connection
  • GUI, Telnet, and SSH system monitoring via Ethernet
  • Browser-based or Java-based RAIDWatch manager software
  • Firmware-embedded manager via RS-232C (audio jack) that is platform independent
  • Widest range of event notification methods including email, LAN broadcast, fax, SNMP traps, SMS, and MSN
  • LCD keypad panel to all configuration options
  • Event log in reserved space; Administrator's activity log
  • Variable logical drive options per DIMM size
  • Module status LED indicators:
    • Two (2) per drive tray
    • Seven (7) per controller module
    • One (1) per power supply unit
    • One (1) per BBU module
    • Two (2) per cooling module
  • Presence detect & thermal sensors via I 2 C bus

Physical/Electrical

Interfaces

  • Four (4) SFP host ports for 4Gb/s DAS or SAN connections
  • One (1) Fast Ethernet management port
  • Two (2) serial COM port (38400, n, 8, 1)

Power Supply Module

Redundant hot-swappable power supplies with PFC
Input
100VAC at 9A, 240VAC at 4.5A with PFC (auto-switching)
47 to 63Hz
Output
(Maximum output: 530 Watts)
+12.0V
32A max.
+ 5.0V
32A max.
+ 3.3V
30A max

Cooling Module

Redundant dual-thermal-fan cooling modules
Maximum air flow
High speed: 90CFM
Low speed: 70CFM

Environmental Specifications

Operating temperature:
5° to 40° C (35° C if battery is applied)
Non-operating temperature:
- 40° to 60° C
Relative humidity:
5 to 95%, non-condensing
Operating altitude:
Operating: 0 to 10,000 ft

Dimensions

  • Without protrusions: 131H x 446.2W x 500D mm
  • With protrusions: 131H x 485W x 532D mm
  • Package dimensions: 476H x 592W x 695D mm

System weight

  • Net weight: 34kg
  • Gross weight: 32kg (without drives)